QC Series 80t/h Waste Heat Boilers:
Model No.:QC Series
Fuel:waste heat
Usage:industry
Type:natural circulation
QC Series 80t/h Waste Heat Boilers are designed for gas-making furnace waste recycling system, which is the use of integrated waste in the system burning waste
QC Series 80t/h Waste Heat Boilers are designed for gas-making furnace waste recycling system, which is the use of integrated waste in the system burning waste heat boiler furnace dust fume produced a device to generate superheated steam. Features of
QC Series 80t/h Waste Heat Boilers are:
1.energy-saving to achieve thermal energy utilization.QC Series 80t/h Waste Heat Boilers are to use micro-dust concentration in flue gas remaining heat of waste recycling systems can be used for power generation, production, life of superheated steam.It does not use disposable fuel, so it has the characteristics of energy-saving and comprehensive utilization of energy.
2.furnace dust. it is conducive to environmental protection.
Due to the flue gas contains large amounts of coarse dust, the boiler uses combined inertia separation principle and gravitational separation principle to achieve separation of dust, reducing soot content.
3. low resistance, running economy.
QC Series 80t/h Waste Heat Boilers heating surface by adjusting the flow rate of flue gas flow cross-sectional area to achieve the design, reducing the bulk resistance, conducive to the integration with other devices and reduce system power consumption.
4. compact.it looks neat in appearance.
Basic characteristics of 80t/h Waste Heat Boiler
1.boiler specification
index | parameter |
rated evaporation | 80t/h |
rated steam temperature | 485℃ |
rated steam pressure | 5.29MPa |
feed water temperature | 95℃ |
exhaust gastemperature | 150℃ |
boiler design efficiency | 82.1% |
import of boiler flue gas | 200000Nm3/h |
import of boiler flue gas temperature | 950℃ |
import of boiler flue gas dust content | 1825g/Nm3 |
2.boiler structure
QC Series 80t/h Waste Heat Boilers are for gas furnace waste recycling systems.Boiler is tunnel layout according to the flue gas flow direction.Boiler main heating surface layout water screen,two superheater,convection tube bank,three economizer and two air preheater.Boiler adopts the type ofsingle drum horizontal natural circulation
water tube.Flue dust is discharged from furnace through water screen,superheater,convection tube bank,economizer and two air preheater.
3.boiler pressure parts water volume table
parts | water volume m3 | remarks |
drum | 13.8 | the length of the straight section |
superheater | 5.8 | include the header and tube |
water pipe system | 35.2 | include the header and tube |
economic | 14.1 | include the header and tube |
total | 68.9 | |
4.Schedule
Boiler Feed Water Quality
boiler type | boiler superheated steampressureMpa | hydrogen conductivity(25℃)/ μS/cm | hardness | dissolved oxygenb | iron | copper | sodium | Sio2 |
μmol/L | μg/L |
standard values | Expectations | standard values | Expectations | standard values | Expectations | standard values | Expectations |
drum boiler | 3.8-5.8 | - | - | ≤2.0 | ≤15 | ≤50 | ≤10 | - | - | - | ensure that the steam silicastandard |
5.9-12.6 | ≤0.3 | - | - | ≤7 | ≤30 | ≤5 | - | - | - |
12.7-15.6 | ≤0.3 | - | - | ≤7 | ≤20 | ≤5 | - | - | - |
>15.6 | ≤0.15a | ≤0.1 | - | ≤7 | ≤15 | ≤3 | ≤2 | - | - | ≤20 | ≤10 |
once-through boiler | 5.9-18.3 | ≤0.15 | ≤0.1 | - | ≤7 | ≤10 | ≤3 | ≤2 | ≤5 | ≤2 | ≤15 | ≤10 |
>18.3 | ≤0.15 | ≤0.1 | - | ≤7 | ≤5 | ≤2 | ≤1 | ≤3 | ≤2 | ≤10 | ≤5 |
a no condensatedemineralization system in unit, hydrogen conductivity in the water supplyshould not exceed 0.30μS/cm. b When oxygenated, indicators in table 4 control ofdissolved oxygen. |
Steam Quality
superheated steam pressure/Mpa | Na (μg/kg) | Hydrogen conductivity(25℃)/(μS/cm) | Sio2 (μg/kg) | iron (μg/kg) | copper (μg/kg) |
standard values | expected value | standard values | expected value | standard values | expected value | standard values | expected value | standard values | expected value |
3.8-5.8 | ≤15 | - | ≤0.30 | - | ≤20 | - | ≤20 | - | ≤5 | - |
5.9-15.6 | ≤5 | ≤2 | ≤0.15a | ≤0.10a | ≤20 | ≤10 | ≤15 | ≤10 | ≤3 | ≤2 |
15.7-18.3 | ≤5 | ≤2 | ≤0.15a | ≤0.10a | ≤20 | ≤10 | ≤10 | ≤5 | ≤3 | ≤2 |
>18.3 | ≤3 | ≤2 | ≤0.15 | ≤0.10 | ≤10 | ≤5 | ≤5 | ≤3 | ≤2 | ≤1 |
A No condensate demineralization system in unit,hydrogen conductivity of steam standard value is no greater than 0.30μS/cm,Expectationsis less than 0.15μS/cm. |
We by the abundant technical force, perfect detection means, strict quality management, sophisticated processing equipment, has its place in the same industry. Our company strictly abide by equality and mutual benefit, quality first, customer supreme principle, is willing to provide warm and thoughtful pre-sale service.
Our corporate culture: outstanding service quality, strict implementation of standards, the system composition, the consummation post-sale service.