240t coal-fired circulating fluidized bed boiler has the feature as follow:
1 Boiler Main Working Parameters
Rated Evaporation 240 t/h
Rated Steam Temperature 540 ℃
Rated Steam Pressure (Gauge) 9.8 MPa
Feed Temperature 215 ℃
Design Thermal Efficiency 91.70 %
Design Fuel Lignite
Application Fuel bituminous coal, anthracite, lean coal, lignite,coal washing, coal gangue
2 Boiler Basic Dimensions
The width of the furnace 11010 mm
Furnace depth 5490 mm
Furnace roof tube elevation 36732 mm
The front and back walls set box elevation 37700 mm
Drum center line elevation 39700 mm
Boiler width 21400 mm
Boiler depth 25800 mm