DETAILSFOR BOILERSYSTEM
1. Plant type: Pulp producer from forestry materials.
2. Gas Composition: Water content is approximately 22%.
Dust emission: 50 mg/Nm3
CO emission: 0.25 mg/Nm3
For organic compounds: 50 mg/m3, expressed as carbon. Moisture: typical
3. Steam produced: 35t/h, 450°C, 40 bar
4. Turbine properties:
Inlet Steam parameters: Steam pressure= 40 bar
Steam temperature= 450°C
Outlet Steam parameters (superheated): Steam pressure= 3.5 barg
Steam temperature = 190°C
5. Excitation voltage generator is 6 kV.
6. Water cooling should be adopted.
7. Scope: EP (Engineering + Procurement)
a. Boiler
b. WHR unit for maximum power generation with condenser, turbine, generator,
automation, etc. c. Cooling system
d. Water treatment unit e. Step-up transformer
f. Plant for drying fuel
g. Silo with the eight-hour fuel supplies
h. Engineering, Drawings, Commissioning, Supervising
8. All equipments' price should be given as FOB.
9. A suggested flow sheet is given in the appendix. Technology supplier may or may not use
such an arrangement. It is up to the supplier's process solution.
We by the abundant technical force, perfect detection means, strict quality management, sophisticated processing equipment, has its place in the same industry. Our company strictly abide by equality and mutual benefit, quality first, customer supreme principle, is willing to provide warm and thoughtful pre-sale service.
Our corporate culture: outstanding service quality, strict implementation of standards, the system composition, the consummation post-sale service.
Coal-fired Industrial Steam Boilers Furnace:
Output:Steam
Structure:Water/fire Tube
Fuel:Coal-fired
Usage:Industrial